SPC4000 Pressure Calibrator


Features and Specifications

 

*** The SPC4000 is discontinued. Per Mensor, the SPC4000 (or CPC6000) reached End-Of-Sale in December, 2019. The SPC4000/CPC4000 has an expected End-Of-Life date of December 31, 2023 (including transducers). These units can only be service / repaired if parts are available. The suggested replacement is the SPC4050 and 4050 transducers. Note that SPC4000 transducers will work in SPC4050 units, but new SPC4050 transducers will NOT work in a SPC4000. ***

 

  • Automated DSA & ZOC calibrations
  • 0.01% FS Accuracy
  • Up to 4 calibration ranges, 0.36 to 750 psig
  • Removable/interchangeable transducers
  • Bench or rack mounted
  • Color touch screen
  • Based on the Mensor CPC6000 pressure calibrator
Application
The SPC4000 pressure calibrator can perform automated multipoint calibrations and offset corrections on demand to DSA & ZOC pressure scanners. In order to do this, the calibrator must be used with the Scanivalve SPCPLU. The reference side of the gauge transducers can be connected to an alternate remote location (tunnel static, elevated line pressure, static basket, etc). The calibrator can also send known pressures to all of the DSA/ZOC sensors to insure they are reading correctly (System Validation).  The calibration system can be used for many applications including multi-point calibration of DSA and ZOC pressure scanners, zero offset correction, and leak testing. The calibrator can also be used in the local/manual mode utilizing the front panel touch screen or remotely via Ethernet.  It would be used in this standalone mode to regulate and measure pressures to calibrate individual pressure transducers.

Overview
The model SPC4000 pressure calibrator is designed to provide automated calibration of Scanivalve Corp’s DSA and ZOC pressure scanners. The calibration system consists of 3 components:
1. The heart of the calibration system is the Scanivalve pressure calibrator, model SPC4000. The SPC4000 calibrator has up to two independent precision pressure regulators. Each regulator can have up to two gauge transducers; thus up to 4 transducers per calibrator.
2. Scanivalve’s Pneumatic Logic Unit (SPCPLU) is required for automated DSA & ZOC calibrations. This unit contains the pneumatic solenoid valves and manifolds required to perform single or multi-range calibrations, as well as zero offset corrections.
3. A utility program, PressCal is included with the SPC4000. It performs automated or manual calibrations on all DSA and ZOC pressure scanners by controlling the pressure calibrator and SPCPLU.  PressCal updates the module calibration coefficient files and generates “as received” and calibration validation reports.

Photos

spc4000_cmyk

(Click photo to enlarge)

Downloads

Support