Features and Specifications
Application
The ZOCEIM is designed to be used in the confined space in wind
tunnel models. It is small in size and comes with a mounting
bracket that makes it easy to install. It can also accept input
signals from signal conditioned thermocouples, RTD, strain gauges,
or individual transducers for pressure, RPM, etc. It can be mixed
with other ZOC pressure scanning modules within a system.The ZOCEIM is designed to be used in conjunction with
Scanivalve’s Ethernet-based
ERAD4000 or
DSM4000 pressure measurement systems. The ZOCEIM can also be
used with a customer’s “in-house” data systems.
The ZOCEIM is designed to be used in the confined space in wind
tunnel models. It is small in size and comes with a mounting
bracket that makes it easy to install. It can also accept input
signals from signal conditioned thermocouples, RTD, strain gauges,
or individual transducers for pressure, RPM, etc. It can be mixed
with other ZOC pressure scanning modules within a system.The ZOCEIM is designed to be used in conjunction with
Scanivalve’s Ethernet-based
ERAD4000 or
DSM4000 pressure measurement systems. The ZOCEIM can also be
used with a customer’s “in-house” data systems.
Overview
The ZOCEIM is designed to multiplex and amplify up to 16 or 32
differential analog inputs. The analog inputs are multiplexed and
then fed into an instrument grade amplifier. The amplifier’s
selectable gain is factory set at 1, 10, 100, or 1000 and can be
reset in the field.
An additional circuit may be factory installed to provide an
excitation voltage for strain gauges, RTD’s, or pressure
transducers. This circuit will provide a +5Vdc at 50 mA, or
optional excitation voltages of 7 and 10 volts on special
order.
The ZOCEIM utilizes the same 15 pin electrical connector as the
ZOC pressure scanners.
The ZOCEIM is designed to multiplex and amplify up to 16 or 32
differential analog inputs. The analog inputs are multiplexed and
then fed into an instrument grade amplifier. The amplifier’s
selectable gain is factory set at 1, 10, 100, or 1000 and can be
reset in the field.
An additional circuit may be factory installed to provide an
excitation voltage for strain gauges, RTD’s, or pressure
transducers. This circuit will provide a +5Vdc at 50 mA, or
optional excitation voltages of 7 and 10 volts on special
order.
The ZOCEIM utilizes the same 15 pin electrical connector as the
ZOC pressure scanners.